Clinical Verification of Accuracy of Noninvasive Blood Glucose Monitor Based on Metabolic Heat Conformation Method

Clinical Verification of Accuracy of Noninvasive Blood Glucose Monitor Based on Metabolic Heat Conformation Method
Author :
Publisher :
Total Pages :
Release :
ISBN-10 : OCLC:1163807299
ISBN-13 :
Rating : 4/5 ( Downloads)

Book Synopsis Clinical Verification of Accuracy of Noninvasive Blood Glucose Monitor Based on Metabolic Heat Conformation Method by : Li Ang

Download or read book Clinical Verification of Accuracy of Noninvasive Blood Glucose Monitor Based on Metabolic Heat Conformation Method written by Li Ang and published by . This book was released on 2017 with total page pages. Available in PDF, EPUB and Kindle. Book excerpt: Background: As a global chronic disease, diabetes is associated with high morbidity and cannot be fully cured with current technology. In order to achieve better long-term control of glucose, it requires continuous monitoring of metabolic indices. The most commonly used glucose monitor is finger stick testing glucose meters. When using it as a method for frequent glucose monitoring, it can cause physical discomfort, infection risk and contradiction. Noninvasive glucose monitoring can accomplish painless, risk-free, low-cost and frequent testing of glucose, which is an ideal method for self-monitoring of glucose. Aims: To verify the accuracy of noninvasive blood glucose monitor based on metabolic heat conformation method in patients with type 2 diabetes. The Noninvasive Glucose Monitor: Based on the theory of metabolic heat conformation method, Tsinghua University and Beijing Sunicare Medical Technologies Co., Ltd. developed a noninvasive glucose monitor. The monitor includes a host and a probe, as shown in Fig. 1. The probe is like a finger clip and the sensors are located inside the probe. The host is like an ipad, which is used for human-computer interaction, control the signal acquisition, data processing and result presenting.The Clinical Trial Design: The recruited type 2 diabetes subjects arrived at the test center before 8 am, then took a rest for 30 minutes to make sure the volunteers are in heat balance state with the environment. The fasting calibration was done first, then the noninvasive test was performed 20 minutes later. The fingertip blood and serum plasma glucose test were performed immediately after the noninvasive test, and the fasting glucose test was finished. The subjects then ate 80g noodles in 15 minutes. Then in 2 hours postprandial, the noninvasive test, fingertip blood test and serum plasma test were conducted in sequence. All the three tests were performed two times, the average of the two results was taken.Results: A total of 254 type 2 diabetes subjects were enrolled, including 118 female and 136 male, with an average age of 59.3 years. Comparison of the noninvasive glucose results and the serum blood glucose result: overall glucose range was 4.0-23.8 mmol/L, the correlation was 0.6902, the RMSE (root-mean-square error) was 2.668 mmol/L; the fasting glucose range was 4.0-17.3 mmol/L, the correlation was 0.8394, the RMSE was 1.855 mmol/L; the 2 hours postprandial glucose range was 4.7-23.8 mmol/L, the correlation was 0. 5393, the RMSE was 3.290 mmol/L. The results in the Parkersu2019 error grid were shown in Fig. 3 and Tab. 1. The fasting results were showed in black and the postprandial results were showed in red.Discussion: The noninvasive blood glucose monitor based on metabolic heat conformation method showed a good correlation with the serum glucose in fasting state, while in postprandial state the correlation reduced. This may related to the greater variability of the parameters of local circulation state, temperature and humidity in postprandial state. The method requires the user and the environment are in heat balance state, which is not easy to quantify. We need to make a trade-off between test convenience and accuracy, rest in the environment for 20 to 30 minutes is a suitable choice. It is suggested that, with a further technical improvement or more specific use conditions, the noninvasive blood glucose monitor based on metabolic heat conformation method have a great prospect in noninvasive glucose monitoring in clinical use.


Clinical Verification of Accuracy of Noninvasive Blood Glucose Monitor Based on Metabolic Heat Conformation Method Related Books

Clinical Verification of Accuracy of Noninvasive Blood Glucose Monitor Based on Metabolic Heat Conformation Method
Language: en
Pages:
Authors: Li Ang
Categories:
Type: BOOK - Published: 2017 - Publisher:

DOWNLOAD EBOOK

Background: As a global chronic disease, diabetes is associated with high morbidity and cannot be fully cured with current technology. In order to achieve bette
Automation and Advancement of Non-invasive Continuous Blood Glucose Measurements
Language: en
Pages: 100
Authors: Andrew deVries
Categories: Biosensors
Type: BOOK - Published: 2021 - Publisher:

DOWNLOAD EBOOK

"Researching the RF application of noninvasive continuous, real time, blood glucose monitoring has been a persistent topic of interest for the research group at
Unraveling the Puzzles of Spectroscopy-based Non-invasive Blood Glucose Detection
Language: en
Pages: 252
Authors: Ishan Barman
Categories:
Type: BOOK - Published: 2011 - Publisher:

DOWNLOAD EBOOK

Disorders of glucose homeostasis, including types 1 and 2 diabetes, represent a leading cause of morbidity and mortality worldwide. Diagnosis and therapeutic mo
Point-of-care testing
Language: en
Pages: 451
Authors: Peter Luppa
Categories: Medical
Type: BOOK - Published: 2018-07-18 - Publisher: Springer

DOWNLOAD EBOOK

The underlying technology and the range of test parameters available are evolving rapidly. The primary advantage of POCT is the convenience of performing the te
Advances in Medical Physics and Healthcare Engineering
Language: en
Pages: 586
Authors: Moumita Mukherjee
Categories: Technology & Engineering
Type: BOOK - Published: 2021-06-17 - Publisher: Springer Nature

DOWNLOAD EBOOK

This book presents research advances in the theory of medical physics and its application in various sectors of biomedical engineering. It gathers best selected