Clinical Study with Short Implants- Relation Among Insertion Torque, Osseointegration and Bone Loss

Clinical Study with Short Implants- Relation Among Insertion Torque, Osseointegration and Bone Loss
Author :
Publisher :
Total Pages :
Release :
ISBN-10 : OCLC:1163806757
ISBN-13 :
Rating : 4/5 ( Downloads)

Book Synopsis Clinical Study with Short Implants- Relation Among Insertion Torque, Osseointegration and Bone Loss by : KArin Gisel Bedoya

Download or read book Clinical Study with Short Implants- Relation Among Insertion Torque, Osseointegration and Bone Loss written by KArin Gisel Bedoya and published by . This book was released on 2017 with total page pages. Available in PDF, EPUB and Kindle. Book excerpt: The use of short implants has gained popularity in the last years, since they have demonstrated high long-term survival and success rates. Also, they allow to reduce treatment time, morbidity and costs compared to bone regeneration procedures. Adequate primary stability and osseointegration are of extreme importance for long-term success of implant therapies.The aim of this study was to assess the relationship between insertion torque (primary stability), premature osseointegration failure and bone loss in patients with short morse taper implants after a 1-year follow-up.6-8mm of vertical bone and 6mm of horizontal bone, evaluated by tomographic examination, were included. A total of 20 morse taper 4 and 5mm in diameter and 5 and 6mm in length dental implants were installed in 11 patients. During implant placement procedures, insertion torques were recorded using a torque wrench and implants were left submerged. After 6 months, second-stage surgeries were performed, signs of premature osseointegration failures evaluated (absence of mobility), provisional crowns delivered and x-rays taken. 1-year after loading, control x-rays were taken. Bone levels were measured in x-rays from the implant platform to marginal bone using ImageJ 1.52d analysis software (National Institutes of Health, Bethesda, USA). Loading and follow-up x-rays were compared to assess the amount of bone loss. Data collected was analyzed using different statistical tests in the SPSS software (IBM Statistics version 21).The mean follow-up time after implant placement was 18.75 u00b1 7 months. Three implants were excluded (15%), two due to mechanical failures and one due to biological failures. Mean values for mesial bone measurements at loading (0.95u00b1 0.74) and at control x-rays (0.88 u00b1 0.83), and for distal bone levels at loading (1.12u00b1 0.92) and at control x-rays (1.08 u00b1 0.91) were used to calculate the amount of bone loss in mesial (0.146) and distal sites (0.326), respectively. Correlation values between insertion torque, mesial (r=-0.240) and distal bone loss (r=0.127) were calculated, as well as for insertion torque and osseointegration (r=0.291).Initial and follow-up values for bone loss showed no statistical differences, thus short implants showed stable bone levels after one year of installation. No relation between insertion torque and bone loss nor insertion torque and osseointegration was found, meaning that initial torque has no direct influence on the amount of bone loss and does not predict osseointegration failures. This study demonstrates the success of short implants in a short-term period.


Clinical Study with Short Implants- Relation Among Insertion Torque, Osseointegration and Bone Loss Related Books

Clinical Study with Short Implants- Relation Among Insertion Torque, Osseointegration and Bone Loss
Language: en
Pages:
Authors: KArin Gisel Bedoya
Categories:
Type: BOOK - Published: 2017 - Publisher:

DOWNLOAD EBOOK

The use of short implants has gained popularity in the last years, since they have demonstrated high long-term survival and success rates. Also, they allow to r
Zero Bone Loss Concepts
Language: en
Pages:
Authors: Tomas Linkevic̆ius
Categories:
Type: BOOK - Published: 2019 - Publisher:

DOWNLOAD EBOOK

Correlation of Insertion and Removal Torque in Polyurethane Foam Devices Simulating Bone Qualities D1 and D2
Language: en
Pages:
Authors: Vogl Susanne
Categories:
Type: BOOK - Published: 2017 - Publisher:

DOWNLOAD EBOOK

Background:Successful osseointegration of dental implants is determined by several factors including implant surface characteristics, bone morphology and metabo
Aging, Osteoporosis, and Dental Implants
Language: en
Pages: 280
Authors: George Albert Zarb
Categories: Health & Fitness
Type: BOOK - Published: 2002 - Publisher: Quintessence Publishing (IL)

DOWNLOAD EBOOK

This text explores the relationship between osteoporosis and osseointegration and offers treatment strategies for patients who require implant-prosthodontic reh
A Multicenter Prospective Randomized Clinical Trial Assessing Implant Design Modifications After 3 Years
Language: en
Pages:
Authors: Raes Stefanie
Categories:
Type: BOOK - Published: 2017 - Publisher:

DOWNLOAD EBOOK

Background:The clinical outcome of implant therapy depends, apart from patient-related factors, on implant-related factors such as surface topography, design an