Evaluation of Bicon Short Implant Longevity in Terms of Annual Bone Loss- 3D FE Study

Evaluation of Bicon Short Implant Longevity in Terms of Annual Bone Loss- 3D FE Study
Author :
Publisher :
Total Pages :
Release :
ISBN-10 : OCLC:1163824439
ISBN-13 :
Rating : 4/5 ( Downloads)

Book Synopsis Evaluation of Bicon Short Implant Longevity in Terms of Annual Bone Loss- 3D FE Study by : Larisa Linetska

Download or read book Evaluation of Bicon Short Implant Longevity in Terms of Annual Bone Loss- 3D FE Study written by Larisa Linetska and published by . This book was released on 2017 with total page pages. Available in PDF, EPUB and Kindle. Book excerpt: Bone loss is the most essential cause of dental implant failure. Comparing to the conventional implants, short implants may fail more rapidly because of their reduced length, especially in case of crestal placement. 0.2 mm mean annual bone loss was recommended as a criterion for implant success. Due to bone loss, even under physiological functional loading, bone overload may occur, which, in turn, provokes complementary bone loss. These processes significantly worsen implant long-term prognosis.The aim of this study was to evaluate and compare load-carrying capacities of the spectrum of fully and partially osseointegrated Bicon short implants to establish their prognosis in posterior maxilla under oblique functional loading.The concept of ultimate functional load (UFL) was proposed (Demenko et al., 2011) to compare load-carrying capacities of fully and partially osseointegrated (0.2 mm annual bone loss) 5.0 (S), 6.0 (M) and 8.0 mm (L) length and 5.0 mm diameter Bicon SHORTu00ae implants. Their 3D models were placed crestally and bicortically in corresponding posterior maxilla segment models with type III bone. They were designed in Solidworks 2016 software and had 1.0 mm cortical crestal and sinus bone layers. Implant and bone were assumed as linearly elastic and isotropic. Elasticity moduli of cortical/cancellous bone were 13.7/1.37 GPa. Bone-implant assemblies were analyzed in FE software Solidworks Simulation. 4-node 3D FEs were generated with a total number of up to 2,532,000. 120.92 N oblique load was applied to the center of 7.0 mm abutment. Von Mises stresses (MESs) were evaluated for bone-implant assemblies to determine UFL magnitudes for fully and partially osseointegrated implants and compare them.Maximal MESs for fully osseointegrated implants (26u202631 MPa) were found on the surface of crestal cortical bone. For partially osseointegrated implants they were discovered in migrating critical points inside crestal cortical bone (27u202632 and 41u202646 MPa for 0.2 and 1.0 mm bone loss). For fully osseointegrated implants, UFL magnitudes were 396u2026465 N. For partially osseointegrated implants and 0.2 bone loss, UFL magnitudes were 377u2026447 N, while for 0.4 mm u2013 356u2026417 N, for 0.6 mm u2013 327u2026366 N, for 0.8 mm u2013 314u2026356 N, and for 1.0 mm u2013294u2026336 N. So, after 5 years in function (1.0 mm bone loss), the following reduction of implant load-carrying capacity was determined: 26, 27 and 28% for S, M and L implants. Thus, all UFL magnitudes were much higher than mean maximal functional loading (120.92 N). Furthermore, for all scenarios, UFL magnitudes were above 275 N maximal functional loading for molar area. Finally, the difference between UFL magnitudes for S and M implants was approximately 5%. Short implant prognosis in terms of gradual bone loss is of crucial importance in implant dentistry. Studied Bicon SHORTu00ae implants were found moderately sensitive to bone loss, at least for 5 years in function and 1.0 mm cortical bone thickness. They were also capable to withstand 275 N maximum functional loading for molar area. Their load-carrying capacity was not substantially dependent on implant length, at least within 5u20268 mm, so this extends their application, especially in bone loss.


Evaluation of Bicon Short Implant Longevity in Terms of Annual Bone Loss- 3D FE Study Related Books

Evaluation of Bicon Short Implant Longevity in Terms of Annual Bone Loss- 3D FE Study
Language: en
Pages:
Authors: Larisa Linetska
Categories:
Type: BOOK - Published: 2017 - Publisher:

DOWNLOAD EBOOK

Bone loss is the most essential cause of dental implant failure. Comparing to the conventional implants, short implants may fail more rapidly because of their r
Impact of Diameter of Short Plateau Implants on Their Load-bearing Capacity in Bone Loss
Language: en
Pages:
Authors: Larisa Linetska
Categories:
Type: BOOK - Published: 2017 - Publisher:

DOWNLOAD EBOOK

Among other reasons, dental implants often fail due to bone loss. Because of reduced length, short implants should be more susceptible to bone loss, especially
Short Implants and Bone Loss - Evaluation of Bone Turnover
Language: en
Pages:
Authors: Igor Linetskiy
Categories:
Type: BOOK - Published: 2017 - Publisher:

DOWNLOAD EBOOK

Short implants are indispensable in posterior maxilla with insufficient bone height. Implant design, bone quality and degree of bone loss predetermine safe func
Impact of Augmented Bone Quality on Success of Bicon Short Implants- FE Study
Language: en
Pages:
Authors: Igor Linetskiy
Categories:
Type: BOOK - Published: 2017 - Publisher:

DOWNLOAD EBOOK

Bicon short implants have successfully proven themselves in the maxillary molar region with insufficient bone height and poor bone quality. To improve crestal b
Outcomes of Short Implants Supporting Fixed Prostheses in Posterior Region - a Retrospective Study of 1-3 Years
Language: en
Pages:
Authors: Young-Jun Lim
Categories:
Type: BOOK - Published: 2017 - Publisher:

DOWNLOAD EBOOK

Background : Short implants are considered to be the simpler and more effective alternative to complicated bone graft surgery in clinical situations with reduce